Skip to content

Spund Settings — Decision Aid

FUERST WIACEK Version 1.0 | Reference — pressure values per fermentation stage | Frequency: as triggered (per stage transition)


Purpose

The spund (pressure relief / regulator on top of every FV) sits at different setpoints depending on what stage the tank is at. Setting it wrong is a real risk — too low during fermentation will cause uncontrolled blow-off; too high during packaging-ready will mean the line can't draw cleanly.

This page is a decision aid, not a procedure. It tells you what value the spund should be at for what stage. The procedure for actually adjusting the spund lives in the relevant SOP for that stage.


The Decision Tree

What stage is the tank at?
│
├─ Tank empty / mid-CIP        → 0 bar       (spund off)
│
├─ Filling (knockout active)   → 0.2 bar     (water-filled spund)
│
├─ Active fermentation         → 0.2 bar
│
├─ Spunded conditioning         → 1 bar       (e.g. lagers, West Coast warm DH)
│  (CO₂ being captured for natural carbonation)
│
├─ Cold crashed / pre-carb      → ~1 bar via CIP arm top pressure
│  (top pressure added if tank dropped below 1 bar after crash)
│
├─ Carbonating (bubbling CO₂)   → 1 bar (spund vents passively as bubbling adds gas)
│
└─ Carbonation complete →       → 0.5–0.6 bar (packaging-ready hold)
   reduce head pressure

Per-Stage Reference

Stage Spund value Set when Source SOP
Tank empty / mid-CIP 0 bar Before tank CIP starts; before opening manway Tank CIP
Knockout — tank filling 0.2 bar, water-filled After end of knockout, before glycol cooling on Wort Knockout
Active fermentation 0.2 bar (continues from knockout) Held throughout fermentation Fermentation Monitoring
Spunded conditioning (lagers, certain styles) 1 bar When recipe calls for natural carbonation hold Recipe-specific
Pre-carb top pressure ~1 bar via CIP arm Before starting carbonation bubbling, if pressure dropped Carbonation — Pre-Conditions
During CO₂ bubbling 1 bar (spund vents passively as gas is added) Throughout the bubbling cycle Carbonation
Packaging-ready / Ready For Filling 0.5–0.6 bar After CO₂ in spec, before advancing Botec to Ready For Filling Carbonation — In Spec

Common Adjustment Triggers

These are the moments where a brewer specifically needs to change the spund:

Trigger From → To Why
Tank CIP complete, ready for knockout 0 → 0.2 bar (water-filled) Set during end-of-knockout sequence
End of fermentation, beginning to crash 0.2 → 1 bar (only if recipe spunded) Capture CO₂ for natural carbonation
Cold crashed, tank below 1 bar pre-bubbling rebuild to ~1 bar via CIP arm Carbonation requires ~1 bar before bubbling starts
CO₂ in spec post-bubbling down to 0.5–0.6 bar Packaging draws cleanly at this pressure
Tank emptied, ready for CIP down to 0 bar Required before opening manway / starting CIP

Common Errors and Fixes

Error Symptom Fix
Spund left at 0.2 bar through carbonation CO₂ keeps blowing off, won't reach target Reset to ~1 bar before bubbling. Carbonate again.
Spund left at 1 bar after carbonation Packaging line foaming / drawing erratically Vent down to 0.5–0.6 bar via CIP arm. Re-check before next packaging run.
Spund left at 0 bar mid-fermentation Tank pulled in air, loss of clean CO₂ blanket Stop. Restore 0.2 bar water-filled. Discuss contamination risk with brewmaster.
Spund 1.5–2 bar during Tank CIP rinse Liquid blown out uncontrolled Set 1.5–2 bar only during the water rinse step of CIP, then return to 0 before sterile air purge. See Tank CIP — water rinse.

Quick Reference Card

For when you're at the tank with a phone in hand:

State Spund
Empty / CIP 0
Filling / fermentation 0.2
Spunded conditioning 1
Pre-carb top pressure / Carbonating ~1
Packaging-ready 0.5–0.6
Tank CIP water rinse step (only) 1.5–2